Polymerization ff Bulk-Fill Composite Resin with Monowave and Polywave Leds: a Literature Review

Authors

  • Francielly de Lemos Medeiros Especializanda em Endodontia pelo Instituto de Pós-Graduação em Odontologia (IOA IOP); Cirurgiã-Dentista pela Universidade Estadual da Paraíba – UEPB, 58429-500, Araruna – PB, Brasil https://orcid.org/0000-0002-8672-7731
  • Marcelo Gadelha Vasconcelos Professor Doutor do Departamento de Odontologia da Universidade Estadual da Paraíba - UEPB, 58429-500, Araruna – PB, Brasil https://orcid.org/0000-0003-0396-553X
  • Rodrigo Gadelha Vasconcelos Professor Doutor do Departamento de Odontologia da Universidade Estadual da Paraíba - UEPB, 58429-500, Araruna – PB, Brasil https://orcid.org/0000-0002-7890-8866

DOI:

https://doi.org/10.21270/archi.v13i1.5621

Keywords:

Curing Lights, Dental, Polymerization, Composite Resins

Abstract

Introduction: Bulk-Fill resin (RBF) allows light curing of increments up to 5 mm thick. It has in its composition alternative photoinitiators that are more sensitive to shorter wavelengths, not corresponding to the emission of monowave light emitting diodes (LEDs) curing units, therefore, polywaves were developed. Objective: to review the literature on RBF and analyze the effectiveness of its polymerization using monowave and polywave LEDs. Methods: a literature review was carried out through scientific articles published between 2012 and 2021 present in databases such as PubMed/Medline, SciELO, Lilacs and Academic Google. Results: In the included studies, four of them obtained a greater degree of monomeric conversion with LEDs polywaves, only one obtained with monowave and in two studies there were no significant differences between the two types. The LEDs polywaves obtained a higher conversion only in the most superficial layers, but beyond 2,5 mm there were no significant differences between the two types. Conclusion: Conclusive literary evidence is needed on which type of LED is best for photoactivation of RBF.

Downloads

Download data is not yet available.

References

Misilli T, Gönülol N. Water sorption and solubility of bulk-fill composites polymerized with a third generation LED LCU. Braz Oral Res. 2017;31:e80.

Akarsu S, Aktuğ Karademir S. Influence of Bulk-Fill Composites, Polimerization Modes, and Remaining Dentin Thickness on Intrapulpal Temperature Rise. Biomed Res Int. 2019; 2019:4250284.

Tardem C, Albuquerque EG, Lopes LS, et al. Clinical time and postoperative sensitivity after use of bulk-fill (syringe and capsule) vs. incremental filling composites: a randomized clinical trial. Braz Oral Res. 2019;33(0):e089.

Gutierrez-Leiva A, Pomacóndor-Hernández C. Comparación de la profundidad de polimerización de resinas compuestas bulk fill obtenida con dos unidades de fotoactivación LED: polywave versus monowave. Odontología Sanmarquina.2020;23(2):131-38.

Besegato JF, Jussiani EI, Andrello AC, et al. Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites. J Mech Behav Biomed Mater. 2019;90:381-87.

Grazioli G, Cuevas-Suárez CE, Nakanishi L, Francia A, de Moraes RR. Physicochemical characterization of two bulk fill composites at different depths. Restor Dent Endod. 2021;46(3):e39.

Fronza BM, Makishi P, Sadr A, et al. Evaluation of bulk-fill systems: microtensile bond strength and non-destructive imaging of marginal adaptation. Braz Oral Res. 2018;32:e80.

Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent.2013;38(6):618-25.

Rocha MG, de Oliveira D, Correa IC, et al. Light-emitting Diode Beam Profile and Spectral Output Influence on the Degree of Conversion of Bulk Fill Composites. Oper Dent. 2017;42(4):418-27.

Lucey SM, Santini A, Roebuck EM. Degree of conversion of resin-based materials cured with dual-peak or single-peak LED light-curing units. Int J Paediatr Dent. 2015;25(2):93-102.

Makhdoom SN, Campbell KM, Carvalho RM, Manso AP. Effects of curing modes on depth of cure and microtensile bond strength of bulk fill composites to dentin. J Appl Oral Sci. 2020;28:e20190753.

Cardoso KA, Zarpellon DC, Madruga CF, Rodrigues JA, Arrais CA. Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite. J Appl Oral Sci. 2017;25(2):140-46.

Motta MS, Medeiros NI, Vasconcelos MG, Vasconcelos RG. Odontologia atual: fundamentação teórica e aspectos clínicos das resinas bulk fill. Odontol. Clín.-Cient.; 2019;18(2):97-102.

Suneelkumar C, Harshala P, Madhusudhana K, Lavanya A, Subha A, Swapna S. Clinical performance of class I cavities restored with bulk fill composite at a 1-year follow-up using the FDI criteria: a randomized clinical trial. Restor Dent Endod. 2021;46(2):e24.

Sandes DCFDS, de Mendonça, ICG. A importância da resina composta Bulk Fill na odontologia moderna. Acervo Saúde. 2021;13(3):e6901

Tsuzuki FM, de Castro-Hoshino LV, Lopes LC, Sato F, Baesso ML, Terada RS. Evaluation of the influence of light-curing units on the degree of conversion in depth of a bulk-fill resin. J Clin Exp Dent. 2020;12(12):e1117-23.

Haugen HJ, Marovic D, Par M, Thieu MKL, Reseland JE, Johnsen GF. Bulk Fill Composites Have Similar Performance to Conventional Dental Composites. Int J Mol Sci. 2020;21(14):5136.

Comba A, Scotti N, Maravić T, et al. Vickers Hardness and Shrinkage Stress Evaluation of Low and High Viscosity Bulk-Fill Resin Composite. Polymers (Basel). 2020;12(7):1477.

Lima RBW, Troconis CCM, Moreno MBP, Murillo-Gómez F, De Goes MF. Depth of cure of bulk fill resin composites: A systematic review. J Esthet Restor Dent. 2018;30(6):492-501.

Mauricio F, Medina J, Vilchez L, Sotomayor O, Muricio-Vilchez C, Mayta-Tovalino F. Effects of Different Light-curing Modes on the Compressive Strengths of Nanohybrid Resin-based Composites: A Comparative In Vitro Study. J Int Soc Prev Community Dent. 2021;11(2):184-89.

Rueggeberg FA, Giannini M, Arrais C, Price R. Fotopolimerização em odontologia e implicações clínicas: uma revisão da literatura. Pesq oral bras. 2017;31(supl 1):e61.

Santini A, Gallegos IT, Felix CM. Photoinitiators in dentistry: a review. Prim Dent J. 2013;2(4):30-3.

Shimokawa C, Sullivan B, Turbino ML, Soares CJ, Price RB. Influence of Emission Spectrum and Irradiance on Light Curing of Resin-Based Composites. Oper Dent.2017;42(5):537-47.

de Oliveira D, Rocha MG, Correr AB, Ferracane JL, Sinhoreti M. Effect of Beam Profiles From Different Light Emission Tip Types of Multiwave Light-emitting Diodes on the Curing Profile of Resin-based Composites. Oper Dent. 2019;44(4):365-78.

Conte G, Panetta M, Mancini M, Fabianelli A, Brotzu A, Sorge R, Cianconi L. Eficácia de cura de unidades de cura por luz LED de pico único e multipico em resinas compostas contendo tpo com diferentes características cromáticas. Oral Implantol. 2017;10(2):140-150.

Soares CJ, Faria-E-Silva AL, Rodrigues MP, et al. Polymerization shrinkage stress of composite resins and resin cements - What do we need to know?. Braz Oral Res. 2017;31(suppl 1):e62.

Menees TS, Lin CP, Kojic DD, Burgess JO, Lawson NC. Depth of cure of bulk fill composites with monowave and polywave curing lights. Am J Dent. 2015;28(6):357-361.

Ilkiu RE, Sinhoreti MA, Amaral RCD. Eficácia da polimerização das resinas compostas Bulk-fill com as atuais fontes à base de LEDs. Dicas de Dentística. 2015;4(4):61-8.

Silva JMC, Silva ABDNR, de Sá Brandim A, Viana MOS. Influência do uso de diferentes fotopolimerizadores na microdureza de uma resina Bulk-Fill. J Health Sci. 2021;22(3):234-37.

Ribeiro BC, Boaventura JM, Brito-Gonçalves JD, Rastelli AN, Bagnato VS, Saad JR. Degree of conversion of nanofilled and microhybrid composite resins photo-activated by different generations of LEDs. J Appl Oral Sci. 2012;20(2):212-17.

Bortolotto T, Betancourt F, Krejci I. Marginal integrity of resin composite restorations restored with PPD initiatorcontaining resin composite cured by QTH, monowave and polywave LED units. Dent Mater J. 2016;35(6):869-75.

Contreras SCM, Jurema ALB, Claudino ES, Bresciani E, Caneppele TMF. Monowave and polywave light-curing of bulk-fill resin composites: degree of conversion and marginal adaptation following thermomechanical aging. Biomater Investig Dent. 2021;8(1):72-8.

Soto-Montero J, Nima G, Rueggeberg FA, Dias C, Giannini M. Influence of Multiple Peak Light-emitting-diode Curing Unit Beam Homogenization Tips on Microhardness of Resin Composites. Oper Dent. 2020;45(3):327-38.

Bin Nooh AN, Nahedh HA, AlRefeai M, Alkhudhairy F. The Effect of Irradiance on the Degree of Conversion and Volumetric Polymerization Shrinkage of Different Bulk-Fill Resin-Based Composites: An In Vitro Study. Eur J Dent. 2021;15(2):312-19.

Miletic V, Santini A. Micro-Raman spectroscopic analysis of the degree of conversion of composite resins containing different initiators cured by polywave or monowave LED units. J Dent. 2012;40(2):106-13.

Derchi G, Vano M, Ceseracciu L, Diaspro A, Salerno M. Stiffness effect of using polywave or monowave LED units for photo-curing different bulk fill composites. Dent Mater J. 2018;37(5):709-16.

Published

2024-01-30

How to Cite

Medeiros, F. de L., Vasconcelos, M. G., & Vasconcelos, R. G. (2024). Polymerization ff Bulk-Fill Composite Resin with Monowave and Polywave Leds: a Literature Review. ARCHIVES OF HEALTH INVESTIGATION, 13(1), 136–144. https://doi.org/10.21270/archi.v13i1.5621

Issue

Section

Original Articles