The aim of the present study was to report a modified protocol for immediate implant-supported full-arch rehabilitation on three interforaminal implants and two implants placed in the posterior mandible, one on each side. This article describes a treatment protocol that can be used to reduce the time required for the fabrication and placement of an implant-supported prosthesis. It is described a technique that improved patient comfort when compared to conventional technology and propose the possibility of using a denture with internal reinforcement framework with captured abutments.

Descriptors: Dental Implants; Immediate Dental Implant Loading; Denture, Complete.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

Turkyilmaz I, Tözüm TF, Tumer C, Ozbek EN. A 2-year clinical report of patients treated with two loading protocols for mandibular overdentures: early versus conventional loading . J Periodontol, 2006; 77: 1998-2004.

Tallarico M, Meloni SM, Canullo L, Caneva M, Polizzi G. Five-Year Results of a Randomized Controlled Trial Comparing Patients Rehabilitated with Immediately Loaded Maxillary Cross-Arch Fixed Dental Prosthesis Supported by Four or Six Implants Placed Using Guided Surgery. Clin Implant Dent Relat Res. 2015 Oct 7. doi: 10.1111/cid.12380.

Takeshita K, Vandeweghe S, Vervack V, Sumi T, De Bruyn H, Jimbo R. Immediate Implant Placement and Loading of Single Implants in the Esthetic Zone: Clinical Outcome and Esthetic Evaluation in a Japanese Population. Int J Periodontics Restorative Dent. 2015; 35:715-23.

Inchingolo F, Ballini A, Cagiano R, Inchingolo AD, Serafini M, De Benedittis M, Cortelazzi R, Tatullo M, Marrelli M, Inchingolo AM, Vermesan D, Del Corso M, Malcangi G, Diteodoro S, Mura SA, Cantore S, Cortelazzi A, Paduanelli G, Resta G, Muollo F, Cirulli N, Pettini F, Farronato D, De Vito D, Caprio M, Haragus H, Dipalma G. Immediately loaded dental implants bioactivated with platelet-rich plasma (PRP) placed in maxillary and mandibular region. Clin Ter. 2015; 166:e146-52.

Grandi T, Guazzi P, Samarani R, Tohme H, Khoury S, Sbricoli L, Grandi G, Esposito M. Immediate, early (3 weeks) and conventional loading (4 months) of single implants: Preliminary data at 1 year after loading from a pragmatic multicenter randomised controlled trial. Eur J Oral Implantol. 2015; 8:115-26.

Melo AC, Toscano R, Vieira RA, Sartori IA, Bernardes SR, Thomé G. Immediate Loading of Edentulous Mandible With Prefabricated Bars: A Long-Term Study of 7 Years. Implant Dent. 2015; 24:472-6.

Portmann M, Glauser R. Report of a case receiving full-arch rehabilitation in both jaws using immediate implant loading protocols: a 1-year resonance frequency analysis follow-up. Clin Implant Dent Relat Res, 2006; 8: 25-31.

Ostman PO, Hellman M, Wendelhag I, Sennerby L. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont, 2006; 19: 77-83.

Castellon P, Blatz MB, Block MS, Finger IM, Rogers B. Immediate loading of dental implants in the edentulous mandible. J Am Dent Assoc, 2004; 135: 1543-1549.

Vanden Bogaerde L, Rangert B, Wendelhag I. Immediate/early function of Brånemark System TiUnite implants in fresh extraction sockets in maxillae and posterior mandibles: an 18-month prospective clinical study. Clin Implant Dent Relat Res, 2005; 7: 121-30.

Renouard F, Nisand D. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clin Implant Dent Relat Res, 2005; 7: 104-10.

Attard NJ, Zarb GA. Immediate and early implant loading protocols: A literature review of clinical studies. J Prosthet Dent, 2005; 94: 242-258.

Achilli A, Tura F, Euwe E. Immediate/ early function with tapered implants supporting maxillary and mandibular posterior fixed partial dentures: Preliminary results of a prospective multicenter study. J Prosthet Dent, 2007; 97: 52-58.

Publicado

2016-07-12

Cómo citar

Gennari Filho, H., Mazaro, J. V. Q., Goiato, M. C., & Turcio, K. H. L. (2016). A modified method for immediate loading and reinforced metal framework overdenture: clinical case. ARCHIVES OF HEALTH INVESTIGATION, 5(3). https://doi.org/10.21270/archi.v5i3.1321

Número

Sección

Artigos