Placa Oclusal Confeccionada en el Flujo Digital como auxiliar en el Tratamiento de la Disfunción Temporomandibular – Reporte de Caso

Autores/as

  • Ludimila Honorato Bertoldo Programa de Pós - Graduação da Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas, 37130-001 Alfenas – MG, Brasil https://orcid.org/0009-0004-5159-3229
  • Julia Vaz Nunes Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas, 37130-001 Alfenas – MG, Brasil https://orcid.org/0009-0003-5368-3458
  • Lucas Henrique de Oliveira Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas, 37130-001 Alfenas – MG, Brasil https://orcid.org/0009-0009-0934-0275
  • Francisca Isabel Ruela Clínica Integrada II, Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas, 37130-001 Alfenas – MG, Brasil
  • João Ermelindo de Assis Costa Clínica Integrada II, Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas,37130-001 Alfenas – MG, Brasil https://orcid.org/0009-0005-0721-4794
  • Lísia Aparecida Costa Gonçalves Clínica Integrada III, Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas, 37130-001 Alfenas – MG, Brasil https://orcid.org/0000-0002-2879-4055
  • Frederico dos Reis Goyatá Clínica Integrada III, Faculdade de Odontologia, UNIFAL-MG Universidade Federal de Alfenas, 37130-001 Alfenas – MG, Brasil https://orcid.org/0000-0002-7877-2188

DOI:

https://doi.org/10.21270/archi.v13i6.6398

Palabras clave:

Placas Oclusales, Trastorno Temporomandibular, Diseño Asistido por Computadora, Informe de Caso

Resumen

El uso de Placas Oclusales como coadyuvantes en el tratamiento de pacientes con Disfunciones Temporomandibulares está bien establecido en la literatura y reafirmado en la práctica clínica. Durante muchos años, la fabricación clínica y de laboratorio utilizando el método analógico ha producido resultados clínicos eficientes. Con el advenimiento del flujo de trabajo digital en Odontología, que reduce el malestar de los pacientes durante las etapas de moldeado y mas rápido las etapas de laboratorio, han surgido preguntas sobre su aplicabilidad en la fabricación de las placas oclusales. Este trabajo presenta un informe de caso que detalla los pasos involucrados en la fabricación de una placa oclusal desarrollada a través del flujo de trabajo digital. Se seleccionó a un paciente que presentaba signos y síntomas de dinfuncione temporomandibular en la Clínica Integrada de la Facultad de Odontología de la Universidad Federal de Alfenas. Las etapas clínicas y de laboratorio fueron documentadas con registros fotográficos de cada paso clínico. Los resultados obtenidos mostraron una reducción significativa en el número de sesiones y un menor ajuste oclusal de la placa.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

International Classification of Orofacial Pain, 1st edition (ICOP). Cephalalgia. 2020;40(2):129-221.

Schiffman E, Ohrbach R, Truelove E, Look J, Anderson G, Goulet JP et al. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†. J Oral Facial Pain Headache. 2014;28(1):6-27.

Chan NHY, Ip CK, Li DTS, Leung YY. Diagnosis and Treatment of Myogenous Temporomandibular Disorders: A Clinical Update. Diagnostics (Basel). 2022;12(12):2914.

Zhang ZP, Wang CC, Song LX, Liu L, Wang MQ, Liu JG. [Analysis of the clinical manifestations of 3 425 patients with orofacial pain of temporomandibular disorders]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2021;56(12):1244-1252.

Patzelt SBM, Krügel M, Wesemann C, Pieralli S, Nold J, Spies BC, Vach K, Kohal RJ. In Vitro Time Efficiency, Fit, and Wear of Conventionally- versus Digitally-Fabricated Occlusal Splints. Materials (Basel). 2022;15(3):1085.

Zhang SH, He KX, Lin CJ, Liu XD, Wu L, Chen J, Rausch-Fan X. Efficacy of occlusal splints in the treatment of temporomandibular disorders: a systematic review of randomized controlled trials. Acta Odontol Scand. 2020;78(8):580-89.

Albagieh H, Alomran I, Binakresh A, Alhatarisha N, Almeteb M, Khalaf Y, Alqublan A, Alqahatany M. Occlusal splints-types and effectiveness in temporomandibular disorder management. Saudi Dent J. 2023;35(1):70-9.

Denardin ACS, do Nascimento LP, Valesan LF, Da Cas CD, Pauletto P, Garanhani RR, Januzzi E, Hilgert LA, de Souza BDM. Disocclusion guides in occlusal splints on temporomandibular disorders and sleep bruxism: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol. 2023;135(1):51-64.

Berli C, Thieringer FM, Sharma N, Müller JA, Dedem P, Fischer J, Rohr N. Comparing the mechanical properties of pressed, milled, and 3D-printed resins for occlusal devices. J Prosthet Dent. 2020;124(6):780-86.

Grymak A, Waddell JN, Aarts JM, Ma S, Choi JJE. Evaluation of wear behaviour of various occlusal splint materials and manufacturing processes. J Mech Behav Biomed Mater. 2022;126:105053.

Sun X, Feng Y, Jiao Y, Liu W. Fully digital workflow for the fabrication of occlusal stabilization splints based on individual mandibular movement. J Dent. 2024;141:104826.

Hardy RS, Bonsor SJ. The efficacy of occlusal splints in the treatment of bruxism: A systematic review. J Dent. 2021;108:103621.

Algabri R, Alqutaibi AY, Elkadem AHE, Maher EA. Patient’s satisfaction and muscles activity after management of temporomandibular disorders patients using computer-aided design/computer-aided manufacturing versus conventional occlusal splints (randomized clinical trial). Int Dent Med J Adv Res. 2017;3:1-8.

Alqutaibi AY, Algabri R, Ibrahim WI, Borzangy S. Does the facebow affect the outcome of CAD/CAM occlusal splint. Randomized clinical trial. Saudi Dent J. 2021;33(7):628-34.

Almeida MVC, Teodoro MKR, Veloso NA. IMPRESSÃO 3D E SUA APLICABILIDADE NA REABILITAÇÃO ORAL. BJSCR. 2020;33:105-

Veneza P, Lo Muzio L, De Furia C, Torsello F. Digital manufacturing of occlusal splint: From intraoral scanning to 3D printing. J Osseointegration. 2019;11:535-9.

Wesemann C, Spies BC, Schaefer D, Adali U, Beuer F, Pieralli S. Accuracy and its impact on fit of injection molded, milled and additively manufactured occlusal splints. J Mech Behav Biomed Mater. 2021;114:104179.

Nota A, Ryakhovsky AN, Bosco F, Tecco S. A full digital workflow to design and mill a splint for a patient with temporomandibular joint disorder. Appl Sci. 2021;11:372.

Berntsen C, Kleven M, Heian M, Hjortsjö C. Clinical comparison of conventional and additive manufactured stabilization splints. Acta Odontol. Scand. 2018;4:81-9.

Perea-Lowery L, Gibreel M, Vallittu PK, Lassila L. Evaluation of the mechanical properties and degree of conversion of 3D printed splint material. J Mech Behav Biomed Mater. 2021;115:10425.

Publicado

2024-06-26

Cómo citar

Bertoldo, L. H. ., Nunes, J. V., Oliveira, L. H. de, Ruela, F. I., Costa, J. E. de A., Gonçalves, L. A. C., & Goyatá, F. dos R. (2024). Placa Oclusal Confeccionada en el Flujo Digital como auxiliar en el Tratamiento de la Disfunción Temporomandibular – Reporte de Caso. ARCHIVES OF HEALTH INVESTIGATION, 13(6), 1929–1934. https://doi.org/10.21270/archi.v13i6.6398

Número

Sección

Original Articles