Study of the Vickers hardness and corrosion behavior of experimental Ti-Mo alloy in dental office bleaching agents

Autores

  • Maria Cristina Rosifini Alves Rezende https://orcid.org/0000-0002-1327-9667
  • Juliana Caires Felipe
  • Roberto Zenhei Nakazato
  • Conceição Aparecida Matsumoto Dutra
  • André Luiz Reis Rangel
  • João Pedro Justino de Oliveira Limírio
  • Ana Paula Rosifini Alves Claro

DOI:

https://doi.org/10.21270/archi.v6i10.2249

Resumo

At present, titanium and its alloys stand out for their mechanical and biological properties. Vickers hardness and the effect of 15%, 22% and 35% hydrogen peroxide (H2O2) on Ti-10Mo alloy corrosion were evaluated. A conventional double-walled glass cell was used for thermostatization. As reference electrode was used the Ag/AgCl (s)/KClsat and as auxiliary electrode graphite stick. The work electrodes consisted of Ti-10Mo cylinders embedded in polyethylene, with electrical contact by brass wire and silver paint on one end. The electrolyte used was H2O2 in concentrations of 15%, 22% and 35% and potentiodynamic measurements were recorded. The Vickers hardness was evaluated before the treatment using Vickers penetrator under load of 1000g and dwell time of 10s / measurement separately. The results showed an increase in the corrosion values in direct relation with the increase of the H2O2 concentration. At 35% concentration, at constant current of ~ 1.0V the alloy did not passivate, characterizing high corrosion rate. At the concentrations of 15% and 22% the results showed a tendency to pseudopassivation, with release of TiO2 and part of the product of the corrosion becoming semi-adherent to the surface of the working electrode and another part passing through the middle, characterizing intermediate corrosion velocity. It was concluded that higher H2O2concentrations produced higher electrochemical corrosion.

Descriptors: Titanium; Alloys; Surface Properties; Corrosion; Tooth Bleaching Agents.

Downloads

Não há dados estatísticos.

Referências

Alves Rezende MC, Alves AP, Codaro EN, Dutra CA. Effect of commercial mouthwashes on the corrosion resistance of Ti-10Mo experimental alloy. J Mater Sci Mater Med. 2007;18(1):149-54.

de Oliveira JA, do Amaral Escada AL, Alves Rezende MC, Mathor MB, Alves Claro AP. Analysis of the effects of irradiation in osseointegrated dental implants. Clin Oral Implants Res. 2012;23(4):511-4.

Escada AL, Machado JP, Schneider SG, Rezende MC, Claro AP. Biomimetic calcium phosphate coating on Ti-7.5Mo alloy for dental application. J Mater Sci Mater Med. 2011; 22(11):2457-65.

Narita K, Niinomi M, Nakai M. Effects of micro- and nano-scale wave-like structures on fatigue strength of a beta-type titanium alloy developed as a biomaterial. J Mech Behav Biomed Mater. 2014;29:393-402.

Niinomi M. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr. Biomaterials. 2003;24(16):2673-83.

Oliveira NT, Guastaldi FP, Perrotti V, Hochuli-Vieira E, Guastaldi AC, Piattelli A, Iezzi G. Biomedical Ti-Mo alloys with surface machined and modified by laser beam: biomechanical, histological, and histometric analysis in rabbits. Clin Implant Dent Relat Res. 2013;15(3):427-37.

Zhou YL, Luo DM. Microstructure and mechanical properties of Ti–Mo alloys cold-rolled and heat treated. Mater. Charact. 2011; 62, 931–37.

Oliveira NTC, Aleixo G, Caram R, Guastaldi AC. Development of Ti–Mo alloys for biomedical applications: microstructure and electrochemical characterization. Mater Sci Eng A. 2007: 452-3,727-31.

Ho WF, Ju CP, Lin JH. Structure and properties of cast binary Ti-Mo alloys. Biomaterials. 1999; 20(22):2115-22.

Serra G, Morais L, Elias CN, Semenova IP, Valiev R, Salimgareeva G, Pithon M, Lacerda R. Nanostructured severe plastic deformation processed titanium for orthodontic mini-implants. Mater Sci Eng C Mater Biol Appl. 2013; 33(7):4197-202.

Cardoso FF, Ferrandini PL, Lopes ES, Cremasco A, Caram R. Ti-Mo alloys employed as biomaterials: Effects of composition and aging heat treatment on microstructure and mechanical behavior. J Mech Behav Biomed Mater. 2013; 32C:31-8.

Tane M, Akita S, Nakano T, Hagihara K, Umakoshi Y, Niinomi M et al. Peculiar Elastic Behavior of Ti-Nb-Ta-Zr Single Crystals. Acta Mater. 2008; 56: 2856-63.

Jung TK, Semboshi S, Masahashi N, Hanada S. Mechanical properties and microstructures of β Ti-25Nb 11Sn ternary alloy for biomedical applications. Mater Sci Eng C Mater Biol Appl. 2013 ;33(3):1629-35.

Guo Y, Chen D, Lu W, Jia Y, Wang L, Zhang X. Corrosion resistance and in vitro response of a novel Ti35Nb2Ta3Zr alloy with a low Young's modulus. Biomed Mater. 2013; 8(5):055004.

Correa DR, Vicente FB, Donato TA, Arana-Chavez VE, Buzalaf MA, Grandini CR. The effect of the solute on the structure, selected mechanical properties, and biocompatibility of Ti-Zr system alloys for dental applications. Mater Sci Eng C Mater Biol Appl. 2014; 34:354-9.

Gill P, Munroe N, Pulletikurthi C, Pandya S, Haider W. Effect of manufacturing process onthe biocompatibility and mechanical properties of Ti30Ta alloy. J Mater Eng Perform. 2011; 20(4):819-23.

Alves Rezende MCR, Capalbo BC, Louzada MJQ, Rangel ALR, Cintra LA, Oliveira JAG, Lisboa Filho PN, Wada CM, Alves Claro APR. Osseointegration of Ti-30Ta implants without primary stability: effect of tranexamic acid. Mater Sci Forum. 2016;869:918-23.

Wada CM, Rangel ALR, Souza MA, Almeida RS, D´Avila MA, Alves Claro APR, Alves Rezende MCR. Surface Modification of Ti-30Ta Alloy by Electrospun PCL Deposition. Mater Sci Forum. 2016;869:930-4.

Fais LM, Fernandes-Filho RB, Pereira-da-Silva MA, Vaz LG, Adabo GL. Titanium surface topography after brushing with fluoride and flouride free toothpaste simulating 10 years of use. J Dent. 2012; 40(4):265-75.

Haywood VB, Heymann HO. Nightguard vital bleaching. Quintessence Int. 1989; 20(3):173-6.

Singh VP, Uppoor AS, Nayak DG, Shah D. Black triangle dilemma and its management in esthetic dentistry. Dent Res J (Isfahan). 2013; 10(3):296-301.

Wang W, Zhu Y, Li J, Liao S, Ai H. Efficacy of cold light bleaching using different bleaching times and their effects on human enamel. Dent Mater J. 2013; 32(5): 761-6.

Basson RA, Grobler SR, Kotze TJ, Osman Y. Guidelines for the selection of tooth whitening products amongst those available on the market. SADJ. 2013; 68(3):122-9.

Alonso De La Peña V, Rodriguez Carreira A, Corral Aneiros R, López Ratón M, Guitián Rivera F. A study of in vivo degradation of two vital home bleaching gels. Dent Mater J. 2013; 32(4): 654–58.

Al-Salehi SK, Hatton PV,Johnson A, Cox AG, McLeod C. The effect of hydrogen peroxide concentration on metal ion release from dental casting alloys. J Oral Rehabil. 2008 ; 35(4):276-82.

Wang J, Qiao GY. The effect of hydrogen peroxide on the electrochemical corrosion properties and metal ions release of nickel-chromium dental alloys. Shanghai Kou Qiang Yi Xue. 2013; 22(2):137-41.

Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Discoloration of titanium alloy in acidic saline solutions with peroxide. Dent Mater J. 2013; 32(1):19–24.

Rosa JL, Nakazato RZ, Scheneider SG, Alves Claro APR, Alves Rezende MCR. Wettability behavior of nanotubular TiO2 intended for biomedical applications. Arch Health Invest. 2014; 3(5):43-7.

Saini M, Singh Y, Arora P, Arora V, Jain K. Implant biomaterials: A comprehensive review. World J Clin Cases. 2015; 3(1): 52-7.

Assis Assis SL, Wolynec S, Costa I. Corrosion characterization of titanium alloys by electrochemical techniques. Electrochimica Acta. 2006; 51:1815-9.

Noguchi T, Takemoto S, Hatton M, Yoshinari M, Kawada E, Oday Y. Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions. 2008; 27(1):117-23.

Mohsen CA. The effect of bleaching agents on the surface topography of ceramometal dental alloys. J Prosthodont. 2010; 19(1):33-41.

Nakamura K, Yamada Y, Takada Y, Mokudai T, Ikai H, Inagaki R et al. Corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H2O2 on dental metals. Dental Mater J. 2012; 31(6):941-6

Yokoyama K, Ogawa T, Fujita A, Asaoka K, Sakai J. Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide. J Biomed Mater Res A. 2007; 82(3):558-67.

Xie L, Wang XX, Li J. The corrosion behavior of titanium in hydrogen peroxide solution with various additives. Key Engineer Mater. 2007; 330-332(19):1285-88.

Downloads

Publicado

2017-10-31

Como Citar

Alves Rezende, M. C. R., Felipe, J. C., Nakazato, R. Z., Dutra, C. A. M., Rangel, A. L. R., Limírio, J. P. J. de O., & Alves Claro, A. P. R. (2017). Study of the Vickers hardness and corrosion behavior of experimental Ti-Mo alloy in dental office bleaching agents. ARCHIVES OF HEALTH INVESTIGATION, 6(10). https://doi.org/10.21270/archi.v6i10.2249

Edição

Seção

Artigos